(the pictures are copyright by me - Patrick Joericke, ask me if you want a agreement)


Also read the TTSH Calibration guide or ask me for support.


Triangle , the original settings from the factor is wrong  - symmetry(Spike)

Solution:

use a scope and check your waveform and correct this by turning the trimmer TRI Symmetry


Thats not a Sine wave !- wrong settings from factory

Solution:

   

Purity - bends the TRI to a Sine wave - after this check the voltage to 10VPP (adjust the gain)

  



Filter Frequency, the Filter closed at 100hz instead of less 10hz

Solution:

Move 1 VCO to top in the VCF mixer and try to close the Filter, the signal must stop at 10-20hz Initial Frequency settings., not by 100hz or more, just turn the Trimmer as shown on bottom picture. (read the TTSH calibration guide too, to understand what you do)