You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

 

Known Issues and Building tipps for yocto 808 Clone Batch2 - January 2014 pcb version

 

 

Noise section:

Measurement AC !!

Adjust the TM4 trimmer for  130mV on pin 1 of 4558.  

its important to use a good DMM (multimeter), most cheap DMM have in AC voltage measurement with 3digits high failure rates and cant display 160mV  - shows only 0,01.

i highly recommend a 4,5digits or better DMM with 0,1% tolerance

 

i have at least 250mV so changing R127 to 47K ...

 

 

for Handclap section:

http://www.e-licktronic.com/forum/viewtopic.php?f=16&t=146&p=525#p525


hear the issue:

http://m.soundcloud.com/patrickj-ricke/yocto-handclap-issue


808 issue handclap:

http://www.muffwiggler.com/forum/viewtopic.php?t=96102&start=10&sid=d6f73a9fdac17e18f1fde05211f88b3d

copy:

This was a little tricky to figure out:

clap reverb mod -
replace r376 (47k) with 100k pot

This will vary the reverb between full and completely off.
 

C144 must have the correct polarity.. neg to gnd


Cowbell

Range: replace  R44 und R45 with  (xxx kOhm) and (xxkOhm).



  • No labels