You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 14 Next »

Project

Projecttitel: RE-606

Status: ALPHA BUILD

Startdate: 11/2019

Duedate:  01/2020

Manufacture link:https://shop.re-303.com


I´m a Alpha Builder, more infos later.


Build Guide:


BOM:

RE606_BOM_191022.xlsx (First version)

RE606_BOM.v1.3.2-RLS.xlsx (latest version with mouser part numbers)


mouser card: (not approved from me)

https://www.mouser.com/ProjectManager/ProjectDetail.aspx?AccessID=040a0cbc 

add the tactile:  688-SKQEAA 

(wrong here is the 22pF capacitor !!

also the 0.47UF is wrong - its bipolar in the mouser Bom instead of polar ) 


another mouser card is available:

https://www.mouser.com/ProjectManager/ProjectDetail.aspx?AccessID=d17c935ded


http://23.235.199.139/~re303c5/forum/topic/1276-some-hints-from-building-my-re-606/


  • Mainboard
    • CR97 -> R97 and use C110 (1NF parallel)
  • Tom board:
    • CR305 ->  R305 and use C329 (1nf parallel)
    • CR308 -> R308 and use C330 (1nF parallel)


  • The jumper wire strip from the alpha BOM was slightly too short, looks like it was updated in the latest BOM to 3 inch, but I would recommend maybe even getting the 4inch instead of 3inch :
    • 571-FSN-23A-8 (Mouser)
  • The scale switch - while this is by no means correct, this will work - just need to wire it to the board, and its quite small compared to the hole in the cases etc
    • 611-SS-24E06-TG5P (Mouser)

BOM help:

Fuse Resistor 2.7ohm = R237 in PSU:

Mouser:  PR02FS0202708KR500

TME: NFR1W-2R7



Tipps:

in case you dont have the SCALE Switch and want test the RE606 with a Workaround (Bridge Pins instead of a Switch)

, you have to Bridge the switchchassis holes with a cable at the outer mounting holes (same in Re303 ) - otherwise the GND pads/traces of the Instruments  are not connected 


Discussion about the Scale switch:  http://23.235.199.139/~re303c5/forum/topic/514-unobtainium-re606-pre-scale-switch/?tab=comments#comment-12104


Install CR97 (1nF) and R106 from the bottom side otherwise the Mode Switch will not fit.

Issues:


Issue 1: (see service notes from Roland to check the correct layout) 

please respect on the switchboard D404 is in wrong orientation, as described in the BOM


Issue2:

On the switchboard are the capacitor designators wrong labeled !!

C1 = C401  1uF/50V Electrolyte polar

C2= C402 10uF/50V Electrolyte polar

C3= C403 100uF/16V electrolyte polar