Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
Projecttitel: RE-909Status:
Startdate: 10/2020Duedate: 02/2020Updated: 27.April 2021Manufacture link: https://shop.re-303.com/build-it-2/Forum: http://23.235.199.139/~re303c5/forum/forum/11-re-909/ Shop: https://shop.re-303.com Facebook Group: https://www.facebook.com/groups/1657521224406039 |
...
Its an replica - not just another clone
BOM:
RE_909_BOM-BUILDGUIDE_v1.0.4.xlsxRE909BUILDBOMv1.9.zip
changelog:
v.1.0 | release | |
v.1.1 | added IC11 and D30, D31, D33 to ORDERING | |
v.1.2 | added info from christian about cabling | |
v.1.3 | added gnd build notes from Christian, fixed an amount value | |
v.1.4 | changed electrolytic capacitor in safety psu from 25V to 35V. | because its standard to have at AC Rectifier a safety range of multiplier 1.5 - 2 (for example an 18VAC is able to give after the rectifier a 28V-29V DC voltage. regards Patrick |
v.1.5 | added extra alternative options for 10k trimmers (clap) | |
v.1.6 | fixed value in tape section. | new value R311: 820K (old value was 820R) |
" Amp section " | fixed C143 voltage 47uF to 50V. 35V is fine too (comment Patrick) | |
v.1.7 | advisory added for snare drum fix. | |
v.1.8 | added info about cabling and errors in TR-909 service docs | |
v.1.9 | fixed values in high tom, C95 and C97 were reversed | new value C95: 100nF new value C97: 15nF (just swap both capacitors, old value was C95 15nF & C97 was 100nF) |
...