titleUser Manual

...

ISE-NIN Manual 1.0.0.pdf

Panel
titleFirmware

...

30.Nov.2022

First RC 1.0.0 released incl. more Banks/Presets 

for Installation help, please read below.

RC1.0.0 ISE-NIN-30112022.zip

Benedek_bank.syx

Expand
titleold versions

04.Nov.2022:  

new beta including vintage presets

you need to reset preset banks and settings after uploading the new firmware in ISE-NIN.

ISENIN_1.0.2B.zip

if you still have the old beta, you have to install again both files with ST-link  and you need to reset preset banks and settings after uploading the new firmware in ISE-NIN.



08.Oct.2022

1.0b beta :  that’s an beta version, install both files on the devices, start with 1.0b1 and install 1.0b2

In this beta are no presets available !

ISENIN_1.0B_2.hex

ISENIN_1.0B_1.hex


September 2022

0.4/0.7 in current test for beta not released for customers (tested by Patrick)


Note

The DIY version uses the same firmware as the prebuilt versions.

Prebuilt Users can ignore the Firmware update mechanism at the moment , because the firmware is still the same and up to date. (22.Dec.2022)



On this Page are 2 Firmware installation guides described:Please note, there are 2 options described here

  1. for DIY builds which are on beta firmware firmware (deprecated due to RC release)
  2. for DIY builds which are empty ( First time Installation for DIY Builds)
  3. Firmware Updates for Prebuilt Versions (not available yet - because we are still on RC 1.0.0)


.  for DIY builds which are on beta firmware : (depracated)


Expand

1.1 you can use the CubeProgrammer and choose USB instead of STlink. - with following steps:

     1.1.1  press the SHIFT button on ISE-NIN while powering on the device, the OLED shows "DFU mode", (note: windows users have to reboot the PC or windows can’t recognize the DFU-mode)

     1.1.2 on the right upper side in CubeProg. app. choose "USB" and press "Connect"

           Image Modified 

   

     1.1.3 it must be shown as this result...         

             Image Modified

1.1.4 then choose on left hand the functions to upload the 1.0.0_1.hex - it disconnects after programming, 

1.1.5 restart ISE-NIN with shift button again and upload 1.0.0.2_hex and done..

1.1.6 ISE-NIN  restarts with 1.0.0 in the OLED boot sequence.

1.1.7 go in the menu settings in ISE.NIN and proceed a "reset settings".

Don´t forget to upload the additional bank as listed above. (USBMIDI with sysexlib tool etc.)


you have to install both files, the first file can be uploaded and cube programmer disconnects with an error - normal




2. First time - Firmware Installation for DIY Builds

...

***you don't need to restart the ISE-NIN after first programming step, in case the ST-LINK tool hangs, just reconnect the USB cable.

Disconnect and restart ISE-NIN its important to remove the Programmer from the ribbon cable - or the device will not start !! 

Start ISE-NIN and go in the ISE-NIN Menu and perform "reset all settings", otherwise some functions doesn't work.

(do not miss to run the calibration procedure which is described in the ISE-NIN Build guide

Now install /send by USB-MIDI with a sysex tool (sysex librian or other) the above Benedek.sysex file otherwise is the Benedek bank still empty.

perform again a reset all settings and reboot the ISE-NIN after you sent the sysex file, or it can happen that bank is still empty.

there no receiving info on the synth when you send the sysex file to the synth.